Impact of Window Frames Inputs in EnergyPlus on the Estimation of Building Energy Efficiency
DOI:
https://doi.org/10.24215/24226483e026Keywords:
Window frame, EnergyPlus,, Energy simulationAbstract
The design of sustainable buildings makes use of energy simulation tools like EnergyPlus. A key element in energy efficiency is the window, and more specifically the window frame, since it gene-rally has a higher thermal transmittance than the other building envelop components. Moreover, the frame reduces the glazing area, decreasing the solar gain. Therefore, when carrying out a si-mulation in EnergyPlus, it is essential to specify the design of window frames through the correct definition of inputs. In this paper, the different possible options for the modeling of window frames in EnergyPlus are analyzed, then compared with each other through simulations. The results show that the outputs are very sensitive to the inputs lack of accuracy, which highlights the necessity for building designer professionals to be cautious about those aspects in order to obtain reliable simu-lation results.
References
Arasteh, D., Kohler, C., & Griffith, B. (2009). Modeling windows in Energy Plus with simple performance indices. Lawrence Berkeley National Laboratory, LBNL-2804E, 2009
Balter, J., Ganem, C., & Discoli, C. (2012). Auditoría y simulación termoenergética como instrumentos de validación para el estudio y mejo-ramiento de edificios en altura en “ciudades oasis”. Ejemplo de aplicación sobre una unidad de vivienda en la ciudad de Mendoza. Revista Avances en Energías Renovables y Medio Ambiente. 16, pp 05.59-05.66
Barea, G., Esteves, A., Ganem, C., & Flores Larsen, S. (2011). Evaluación energética de ventanas multiacimutales en la ciudad de Mendoza mediante prototipos a escala 1:1 y el programa EnergyPlus. Revista Avances en Energías Renovables y Medio Ambiente. 15, pp 08.173- 08.181
De Gastines, M., Villalba, A., & Pattini, A. (2014). Determinación del Factor K de ventanas. Utilización de programas de simulación de precisión para evaluar el impacto del diseño de marcos y de las condiciones climáticas. Revista Avances en Energías Renovables y Medio Ambiente. Vol. 18, pp 08.35-08.42
De Gastines, M., Correa, E., & Pattini, A. (2015). Evaluación del balance energético de ventanas en Mendoza. Impacto de su tecnología y orien-tación. Revista Avances en Energías Renovables y Medio Ambiente. 13, pp 05.01-05.12
Norma IRAM 11507-4:2001. Carpintería de obra y fachadas integrales livianas: Ventanas exteriores: Parte 4: Requisitos complementarios: Aislación térmica. Instituto Argentino de Normalización. Buenos
Norma ISO 15099:2003. Thermal performance of Windows, Doors and Shading Devices—Detailed Calculations. International Organization for Standardization.
Lyons, P., Wong, J., & Bhandari, M. (2010). A comparison of window modelling methods in EnergyPlus 4.0. Fourth National Conference of IBPSA-USA, New-York, pp. 177-184.
Monroy, M. (1995). Comportamiento térmico de cerramientos soleados. Tesis Doctoral. Universidad de las Palmas de Gran Canaria, Apéndice B.
Norma NFRC 100-2004. Procedure for Determining Fenestration Product U-Factors. National Fenestration Rating Council, United States
Winkelmann, F. (2001). Modeling Windows in EnergyPlus. Seventh International Conference IBPSA, Brazil, pp. 457-464
Downloads
Published
Issue
Section
License
Acorde a estos términos, el material se puede compartir (copiar y redistribuir en cualquier medio o formato) y adaptar (remezclar, transformar y crear a partir del material otra obra), siempre que a) se cite la autoría y la fuente original de su publicación (revista y URL de la obra), b) no se use para fines comerciales y c) se mantengan los mismos términos de la licencia.