Energy Consumption Optimization of a Parametric Design Model

Authors

  • Patricia Edith Camporeale, Dra. Laboratorio de Arquitectura y Hábitat Sustentable. Facultad de Arquitectura y Urbanismo. Universidad Nacional de La Plata
  • Jorge Daniel Czajkowski, Dr. Laboratorio de Arquitectura y Hábitat Sustentable (LAyHS) . Facultad de Arquitectura y Urbanismo. Universidad Nacional de La Plata. - Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET).

DOI:

https://doi.org/10.24215/24226483e041

Keywords:

Bioclimatic indexes, Energy consumption optimization

Abstract

This paper is part of a wider work on energy consumption optimization in parametric bioclimatic design. First, we determine an efficient parametric envelope, which fulfills Law 4458/12 on Thermal Conditioning Standards for Buildings in Buenos Aires City. The envelope also satisfies IRAM 11604 Standard on Admissible Volumetric Coefficient in Heating and IRAM 11659/1 -2 Standard on Admissible Volumetric in Cooling, while adding bioclimatic variables: solar, occupancy and envelope thermal loads. We apply bioclimatic indexes in heating and cooling, which have been previously designed. We obtain building alternatives with equivalent energy-performance but different morphology.
Then, we choose an alternative and optimize maximum fenestration with minimum energy consumption. We look for equilibrium between solar gains, thermal losses, as long as we avoid overheating by means of passive devices. We can conclude that parameterization allows control energy performance of the envelope in real time, lowering costs on designer hours.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Author Biographies

Patricia Edith Camporeale, Dra., Laboratorio de Arquitectura y Hábitat Sustentable. Facultad de Arquitectura y Urbanismo. Universidad Nacional de La Plata

Doctora en Arquitectura y Urbanismo por la UNLP. Doctora en Arquitectura por la Universidad de Sevilla. Mi área experta esla optimización del diseño arquitectónico y urbano a través de la minimización de la demanda energética de la envolvente edilicia, la energía incorporada de los materiales y los residuos de demolición y construcción, en el marco del Ciclo de Vida del edificio. Publiqué trabajos en revistas científicas del primer cuartil (Q1, JCR) y participé de numerosas conferencias en el país y en el exterior presentando mis trabajos.

Jorge Daniel Czajkowski, Dr., Laboratorio de Arquitectura y Hábitat Sustentable (LAyHS) . Facultad de Arquitectura y Urbanismo. Universidad Nacional de La Plata. - Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET).

Jorge Daniel Czajkowski es Arquitecto, Profesor titular de Instalaciones I-II, Director del Laboratorio de Arquitectura y Hábitat Sustentable en la Facultad de Arquitectura y Urbanismo de la Universidad Nacional de La Plata. Es Investigador Independiente del Consejo Nacional de Investigaciones Científicas y Técnicas. Mail: jdczajko@gmail.com, czajko@ing.unlp.edu.ar

References

BEN Balance Energético Nacional, Ministerio de Economía de la República Argentina http://www.energia.gov.ar/contenidos/verpagina.php?idpagina=3366
Camporeale, P., (2012). El uso de algoritmos genéticos en el diseño paramétrico de edificios energéticamente eficientes: el coeficiente G y el consumo anual de energía, Actas del XII Congreso Iberoamericano de Energía Solar (CIES),
Vigo, España
Camporeale, P. y Czajkowski, J.(2015). Índice Bioambiental de Consumo Energético en Edificios aplicado a un Modelo
de Diseño Paramétrico- Actas del II Congreso Internacional de Construcción Sostenible y Soluciones Eco-eficientes-25 al 27 de mayo-de 2015- págs. 629 y ss. ISBN 978-84-617-3964-6.Sevilla- España
Goldberg, D., (1997). ‘Some applications of Genetic Algorithms’ in ‘Genetic Algorithms in Search, Optimization and Machine Learning’, Addison-Wesley, MA, USA, pp. 88-145.
Gonzalo, G. E., (1998). Manual de arquitectura bioclimática. Tucumán: Edicióndelautor Iqbal, Imran etals (2007). Parametric analysis of alternative energy conservation measures in an office building in hot and humid climate Building and Environment, Volume 42, Issue 5, May 2007, Pages 2166-2177
Leach, N etals, (2004). ‘Design by Algorithm’ in ‘Digital tectonics’, Wiley-Academy, UK, pp. 79-87.
Mitchell, M. (1998), ‘ Implementing a genetic algorithm’ in ‘An Introduction to Genetic Algorithms’, The MIT Press, MA, USA, pp. 154-179
Norma IRAM 11507-4 (2012).Carpintería de obra y fachadas integrales livianas. Ventanas exteriores Parte 4.Requisitos complementarios. Aislación térmica. . Instituto Argentino de Normalización. Buenos Aires.
Norma IRAM 11601:(2002). Aislamiento térmico de edificios, métodos de cálculo. Propiedades térmicas de los componentes y elementos de construcción en régimen estacionario. Instituto Argentino de Normalización. Buenos Aires.
Norma IRAM 11603(1996). Acondicionamiento térmico de edificios. Clasificación bioambiental de la República Argentina. Instituto Argentino de Normalización. Buenos Aires.
Norma IRAM 11604 (2001). Aislamiento térmico de edificios. Verificación de sus condiciones higrotérmicas. Ahorro de energía en calefacción. Coeficiente volumétrico G de pérdidas de calor. Cálculo y valores límites- Instituto Argentino
de Normalización y Certificación- 2° ed.-Buenos Aires
Norma IRAM 11605 (1996). Acondicionamiento térmico de edificios, condiciones de habitabilidad en edificios. Valores máximos de transmitancia térmica en cerramientos opacos. Instituto Argentino de Normalización. Buenos Aires.
Norma IRAM 11659 1 y 2-(2004). Aislamiento térmico de edificios. Verificación de sus condiciones higrotérmicas.
Ahorro de energía en refrigeración. Parte 1: Vocabulario, definiciones, tablas y datos para determinar la carga térmica de refrigeración- Parte 2: Edificios para viviendas- Instituto Argentino de Normalización y Certificación-Buenos Aires
Peronato, g. etals. (2015). A parametric design based methodology to visualize building performance at the neighborhood scale- Infoscience- Écolepolytechniquefédérale de Lausanne EPFL
Sadineni,Suresh B.,MadalaSrikanth, Boehm Robert F.- (2011) Passive building energy savings: A review of building envelope components- Renewable and Sustainable Energy Reviews 15 3617–3631
Terzidis, K. (2006). Algorithmic Architecture. Oxford: Architectural Press.
Russell, S. et al, (2010).Beyond classical search in Artificial Intelligence, A Modern Approach, 3rd ed., Prentice-Hall Pearson Education Inc., NJ, USA, pp. 125-128.

Published

2018-07-02

How to Cite

Camporeale, P. E., & Czajkowski, J. D. (2018). Energy Consumption Optimization of a Parametric Design Model. Estudios Del hábitat, 16(1), e041. https://doi.org/10.24215/24226483e041

Issue

Section

Artículos